Cobalt-60 Sealed Sources for Gamma Radiography.

We also offer Industrial Gauging Co-60 Gamma Sources

QSA Global, Inc. is the world-leading supplier of Cobalt-60 (Co-60) sealed radioisotope sources to the industrial gamma radiography industry. Our exclusive and diversified supply chain ensures a reliable, long-term supply of Co-60 to our customers.

QSA Global, Inc.’s Co-60 sealed radioisotope sources are compacted High Specific Activity (HSA), double-encapsulated, and welded for superior quality and safety. 

Our Co-60 sealed radioisotope sources are available in 300 Ci (11.10 TBq) activity. Custom activities may be ordered to meet your specific application needs. 

Designed, tested, and manufactured to the requirements of ISO 9001/EN46001

Co-60 sealed sources next to the SENTRY Series Cobalt Gamma Ray Camera.

Co-60 in Gamma Radiography

Cobalt-60 sealed sources are used throughout the industrial radiography industry to detect structural damage to metal parts. QSA Global, Inc.’s Co-60 sealed sources are used to perform industrial gamma radiography with relatively short exposure time on thicker materials such as heavy castings, thick steel weldments, and concrete.

Material Approximate Material Density Approximate Half-Value Thickness
Concrete 2.35 g/cm3 2.400 in (61.0 mm)
Steel 7.80 g/cm3 0.827 in (21.0 mm)
Lead 11.34 g/cm3 0.500 in (12.7 mm)
Tungsten 17.80 g/cm3 0.310 in (7.9 mm)
Depleted Uranium (DU) 18.70 g/cm3 0.270 in (6.8 mm)

Gamma Energy Range 1.17-1.33 MeV
Steel Thickness 2.0–6.0 in (50-150 mm)
Concrete Thickness 10 to 40 in (200-1,000 mm)
Light Alloys Thickness 1.5–7.5 in (40-190 mm)
Radioisotope Output

 At 1 m per Ci (37 GBq): 1.30 R/hr (13.0 mSv/hr)
At 1 ft per Ci (37 GBq): 14.0 R/hr (140 mSv/hr)

Half-Life 5.27 years
Special Form Certification USA/0377/S-96 

Co-60 Gamma-Ray Source Projectors

QSA Global, Inc.’s Co-60 sealed radioisotope sources are generally in the configuration of a right circular cylinder with an end mounted hemisphere of equivalent diameter. The active material is coaxial with the source capsule.

QSA Global, Inc.’s Co-60 isotope assemblies were designed specifically for use in our Co-60 gamma radiography source projectors to perform weld quality inspection in Fabrication Shops and Shipyards and to investigate the condition of large valves in piping systems.

Co-60 radioisotopes are available for the following current and previous Co-60 gamma-ray source projectors.

System Assembly Number Max Capacity

A424-13
A424-14

330 Ci (12 TBq)
110 Ci (4.07 TBq)
A424-14 110 Ci (4.07 TBq)
680 Series A424-14 110 Ci (4.07 TBq)
741  Series A414-18 33 Ci (1.22 TBq)
684 Series A424-15 11 Ci (407 GBq)

Co-60 Transportation and Support

Worldwide Delivery

We understand that dealing with radioactive materials is complex. Shippers of radioactive materials in regulatory jurisdictions must ensure full compliance with all current and applicable transport regulations.

QSA Global, Inc.’s global network of export specialists and brokers are available to provide you with the expertise needed to solve challenging logistics issues.

Loading & Unloading

QSA Global, Inc. offers a variety of options for loading and unloading Co-60 sealed radioisotope sources to help minimize downtime. Co-60 sealed sources can be loaded and unloaded from your system to the container:
  • By a trained professional we send to your location
  • Locally in your bunker by your trained employees
  • At QSA Global, Inc. headquarters via your local service center

Learn more .

Learn more about QSA Global's Co-60 sealed radioactive sources for gamma radiography:

  • Co-60 Datasheet

 

Ready to Chat?

QSA Global, Inc.'s technical experts are here to help you find the right Co-60 sources for your specific needs.  

Contact Us

Co-60 Disposition.

Co-60 sealed sources that are no longer required must be transferred to a licensed recipient for final disposition. 

Request Disposition