JME ADVANCED INSPECTION SYSTEMS

JME Portable X-Ray Betatron.

JME portable Betatron X-ray systems are a range of compact circular electron accelerators producing a high energy directional X-ray beam. The JME Betatron systems are easy to assemble, operate, and maintain. They contain no moving parts or cooling liquids, so maintenance required on the systems is minimal. They can produce radiographs of very high contrast, sensitivity, and resolution allowing operators to meet the tightest inspection standard.

A wide variety of applications within many sectors of the NDT industry use JME's Betatron systems. Examples include but are not limited to inspecting large forgings, castings, valves, beams, ships hulls, pressure vessels, engine blocks, thick welds, composites, reinforced concrete buildings, bridges, and cargo/security scanning solutions.

JME portable Betatron systems

JME Portable X-Ray Betatron Models

QSA Global, Inc. offers multiple systems within the Betatron range, each with a different maximum energy. The outputs are 2.5, 6, and 7.5 MeV and the  energy output on all systems is variable from 2 MeV through to the maximum energy. Adjustments can be made in 0.1 MeV increments. 

PXB 2-5

PXB 2.5D Betatron

Half Value Layer (HVL) for Steel is 20 mm

Peak X-ray Output 2.5 MeV
Dose Rate at 1 m (3.3 ft) >0.7 R/minute
Focal Spot Size 0.2 x 2.0 mm
Duty Cycle Radiation Beam 75% per hour
Beam Coverage 350 x 350 mm @ 1 m
Radiographic Sensitivity Down to 1%
Supply Voltage Single-phase, 110 V or 220 V, 50/60 Hz
Power Consumption 1.0 kW (4.5 A @ 220 V, 9 A @ 110 V)
PXB 6M 7M-1

PXB 6M Betatron

Half Value Layer (HVL) for Steel is 28 mm

Peak X-ray Output 2 to 6 MeV
Dose Rate at 1 m (3.3 ft) >3 R/minute
Focal Spot Size 0.3 x 3.0 mm
Duty Cycle Radiation Beam 75% per hour
Beam Coverage 250 x 250 mm @ 1 m
Radiographic Sensitivity Down to 1%
Supply Voltage Single-phase, 110 V or 220 V, 50/60 Hz
Power Consumption 2.0 kW (9 A @220 V, 18 A @ 110 V)
Single or Three Phase available upon request
PXB 6M 7M-1

PXB 7.5M Betatron

Half Value Layer (HVL) for Steel is 32 mm

Peak X-ray Output 2 to 7.5 MeV
Dose Rate at 1m (3.3 ft) >5 R/minute
Focal Spot Size 0.3 x 3.0 mm
Duty Cycle Radiation Beam 75% per hour
Beam Coverage 250 x 250 mm @ 1 m
Radiographic Sensitivity 1%
Supply Voltage Single-phase, 110 V or 220 V, 50/60 Hz
Power Consumption 3.0 kW (13.6 A @220 V, 27 A @ 110 V)
Single or Three Phase available upon request